Chromatographic

Chromatographic JQ1 separation was performed on a HILIC column. The mobile phase was composed of acetonitrile-10 mmol/L ammonium formate (86:14, v/v), with a flow rate of 0.4 mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode via positive electrospray ionisation (ESI+) source. The linear calibration range was 0.5 to 200 ng/mL in plasma and 10 to 5000 ng/mL in urine (r(2) >0.99). The intra-and inter-day precision (relative standard deviation, RSD) values were below 15% and the accuracies (relative error, RE) were -7.1% to 2.8%

in plasma and -1.3% to 10.3% in urine at three quality control levels. In human subjects receiving 100 mg tilidine and 8 mg naloxone, mean AUC(0-24) of N3G was IWR-1-endo cost 160.93 +/- 52.77 ng/mLh and mean C-max was 75.33 +/- 25.27 ng/mL. In 24-h urine samples, 8.0% of the dose was excreted in the form of N3G in urine. These results demonstrated a new method suitable for in vivo pharmacokinetic studies of N3G. (C) 2013 Elsevier B.V. All rights reserved.”
“A novel microporous hybrid silica membrane for the separation of carbon dioxide,

fabricated through sol-gel deposition of a microporous Nb-doped ethylene-bridged silsesquioxane layer on a multilayer porous support, was reported. Effect of the calcination temperature on H(2)/CO(2) separation properties of Nb-BTESE membrane was investigated. Low CO(2) permeance was imparted by doping acidic niobium centers into the hybrid silica networks.

Denser hybrid this website silica networks as well as more Lewis acid sites were generated as the calcination temperature elevated, which imparted very low CO2 permeance to the novel hybrid membrane while retaining its relative high H(2) flux in the order of similar to 10(-7) mol m(-2) s(-1) Pa(-1) Dominant densification occurred in the Nb-doped hybrid silica networks when the calcination temperature was lower than 400 degrees C. Meanwhile, the Nb-BTESE membrane showed relatively weak acidity which was induced by niobium doping. Dual effects are working when the heat-treated temperature was higher than 400 degrees C. On the one hand, the increased surface acidity reduced the number of sites and/or affinity for adsorption of CO(2) as the calcination temperature elevated. On the other hand, membrane densification occurred during the calcination process. Therefore, the permselectivity of H(2)/CO(2) for Nb-BTESE membrane could be tuned by altering the calcination temperature. The Nb-BTESE membrane calcined at 450 degrees C showed both relative high hydrogen permeance (similar to 9.7 x 10(-8) mol M(-2) S(-1) Pa(-1)) and excellent H(2)/CO(2) permselectivity (220), as compared with Nb-BTESE membranes calcined at other temperatures. (C) 2011 Elsevier B.V. All rights reserved.

Comments are closed.